1. A three-step shortcut to the right model

Step 1: Set the capacity — how tight is the cap you need to test?
Step 2: Choose the series — do you need PC-generated QC reports?
Step 3: Check the fixture — what is the maximum cap diameter?

2. TNJ vs TNP — the core differences

ItemTNJ (economy)TNP (advanced)
PositioningOn-site sampling, quick readingsQuality management, data traceability
Data storage❌ None✅ 1,000 data sets
USB PC communication❌ None✅ Excel report export
HI/GO/LO tri-colour judgement lamps❌ None✅ Instant pass/fail identification
Statistical functions❌ None✅ Automatic max / min / average
Accuracy±0.5%FS±0.5%FS
Sampling rate1,000 readings / s1,000 readings / s
PriceAbout 70% of the TNPStandard price
Typical userSmall workshops, limited budget, pass/fail onlyMedium and large enterprises, ISO certification, quality records required

3. Selecting by capacity (the most important step)

ModelCapacityCap typeTypical application
TNJ-2 / TNP-20~2N·mLow torque, lightly tightened capsOral-liquid bottles, medicine bottles, cosmetic samples, 5~30 g cream jars
TNJ-5 / TNP-50~5N·mMedium torque, general packaging500 ml drink bottles, sauce bottles, shampoo, 200~500 g food jars
TNJ-10 / TNP-100~10N·mHigh torque, industrial packaging1~5 L agrochemical bottles, lubricant pails, detergent pails, bulk sauce drums

✅ Golden rule: the actual test torque should fall within 20%~80% of full scale.
Example: a measured cap torque of about 2N・m → choose TNJ-5 / TNP-5, not TNJ-10 / TNP-10.

4. Recommendations by industry

4.1 Pharmaceutical / supplements

4.2 Cosmetics / household products

4.3 Food and beverages

4.4 Agrochemicals / chemicals / industrial packaging

5. Common selection mistakes

❌ Mistake✅ Correct approach
"Buy a larger capacity and it will measure anything in future"A large capacity gives poor accuracy at low torque; buying an oversized instrument for small caps wastes resolution
"The TNP has more functions, so it must be better"If PC data export is not needed, the extra cost of the TNP is wasted
"Any fixture that grips will do"Confirm the maximum cap diameter; the standard fixture covers Φ10~Φ180mm, above which a custom fixture is required
"The higher the accuracy the better"±0.5% FS is sufficient for routine cap torque testing; do not pay for unnecessary accuracy
"Hand-held is more convenient"Cap testing requires a bench-mounted instrument. Hand-held use introduces error, and a hand-held force gauge is not recommended for cap torque

6. Configuration checklist

ItemDescriptionRequired?
Main unitTNJ/TNP model in the chosen capacity✅ Required
Standard clamping pinsIncluded as standard; suits round caps✅ Standard
Flat jaw fixtureNeeded for square / irregular caps🔶 Optional
Extension rodNeeded for very tall bottles🔶 Optional
Calibration certificateNeeded for ISO audits🔶 Optional
Carrying caseProtection for field use✅ Standard