I. What sensitivity actually describes
The unit of sensitivity is mm/m, read as "millimetres per metre". What it actually describes is: the height difference produced across a 1 m length of the measured surface when the bubble moves one division. A level rated at 0.02 mm/m, placed on a 1 m long surface, shows a 0.02 mm difference between the two ends for each division the bubble travels.
Converting to an angle makes it clearer: 0.02 mm/m ≈ 0.0011° ≈ 4.1 arcseconds. This is why installation manuals for high-precision machine tools usually state levelling requirements directly as "0.02mm/m" rather than as an angle — it is a quantity that can be read straight off a level.
II. How much do the three grades differ over 300 mm?
Among FSK precision levels currently available, the 0.02, 0.05 and 0.1 mm/m grades account for roughly 47–49 models each and are the clear mainstay. Numbers alone are hard to picture, so here is the same data expressed as "real physical displacement":
| Sensitivity | Height difference over 300 mm | Equivalent angle | Typical use |
|---|---|---|---|
| 0.01 mm/m | 0.003 mm | approx. 2.1″ | Metrology rooms, ultra-precision platforms |
| 0.02 mm/m | 0.006 mm | approx. 4.1″ | Machine tool installation, precision inspection |
| 0.05 mm/m | 0.015 mm | approx. 10.3″ | General equipment installation and annual inspection |
| 0.1 mm/m | 0.030 mm | approx. 20.6″ | Coarse levelling, construction setting-out |
| 0.5 mm/m | 0.150 mm | approx. 1′43″ | Initial setup of anti-vibration / isolation tables |
| 1.0 mm/m | 0.300 mm | approx. 3′26″ | Civil engineering, formwork, masonry |
Only 2 models on the site fall into the 0.01 mm/m grade (FLAA-200, FLAB-200). These are FSK's highest-sensitivity specifications and are noticeably more expensive; unless you need metrology-room calibration, they are generally unnecessary.
III. The sensitivity code inside FSK model numbers
This is the handiest rule, and the one customers ask about most:Across FSK's three main series — precision flat, precision angular and bubble-tube levels — the middle digit of the model number is the sensitivity grade: 1 = 0.02, 2 = 0.05, 3 = 0.1.
A quick check makes it clear; all of the following are 300 mm precision flat levels (JIS Class B):
| Model | Sensitivity | Accuracy class | Nominal size |
|---|---|---|---|
| FAB1-300 | 0.02 mm/m | JIS Class B | 300mm |
| FAB2-300 | 0.05 mm/m | JIS Class B | 300mm |
| FAB3-300 | 0.1 mm/m | JIS Class B | 300mm |
The same rule applies to the angular series (SAB / SLA / SLB) and the bubble-tube series (BTL). So when you see SAB1-300、SLA1-300、SLB1-300 these model numbers, you know without checking a table that they are all 0.02 mm/m.
A second group of series simply writes the sensitivity value into the model number, which is even easier to recognise: the AL0.5-300 and AL1.0-300 mini levels; the S0.02-100, S0.05-100, S0.1-100 and S0.2-100 small levels; and the ADL0.1-500 adjustable long type. In these models the number is the mm/m value itself.
IV. Sensitivity ≠ accuracy class
This is the second common misunderstanding. At the same 0.02 mm/m, the JIS Class A-AA, JIS Class B and general-purpose (standard) grades differ considerably in price, yet the sensitivity figure is exactly the same. The real differences are:
- JIS Class A-AA / JIS Class B: manufactured to JIS B7510 with accuracy better than the standard requires (our specifications note "no JIS marking").
- General-purpose (standard grade): manufactured to FSK's own company standard.
What the grade actually affects is base flatness, the ageing stability of the cast iron, and whether a JIS-compliant calibration certificate can be issued. The test is simple:If the instrument must pass a customer audit or third-party metrology, choose JIS Class B or better; for in-house machine setup and routine daily checks, the standard grade is sufficient.
The three grades map one-to-one at a given size and sensitivity, so you can switch between them directly:
| Sensitivity | JIS Class A-AA (flat / angular) | JIS Class B (flat / angular) | General-purpose (flat / angular) |
|---|---|---|---|
| 0.02 mm/m | FLA1-300 / SLA1-300 | FAB1-300 / SAB1-300 | FLB1-300 / SLB1-300 |
| 0.05 mm/m | FLA2-300 / SLA2-300 | FAB2-300 / SAB2-300 | FLB2-300 / SLB2-300 |
| 0.1 mm/m | FLA3-300 / SLA3-300 | FAB3-300 / SAB3-300 | FLB3-300 / SLB3-300 |
V. Match your application directly
| Application | Recommended sensitivity | Recommended series | Representative models |
|---|---|---|---|
| Levelling machine tools / machining centres | 0.02 mm/m | Precision flat / angular, JIS Class B or better | FAB1-300、SAB1-300 |
| Horizontal and vertical alignment of round shafts and pipes | 0.02 mm/m | V-groove base type (V groove on the bottom face) | FLV1-300 |
| Annual equipment inspection, daily checks | 0.05 mm/m | Precision flat / angular, standard grade | FLB2-300、SLB2-300 |
| Long guideways, large-span surface measurement | 0.05~0.1 mm/m | Bubble-tube levels (up to 500 mm) | BTL1-500、BTL3-500 |
| Installing anti-vibration / isolation tables | 0.5~1.0 mm/m | Mini levels | AL1.0-300 |
| Confined spaces, portable use | 0.05~0.1 mm/m | Portable / small levels | CAL3-100、S0.2-100-80AL |
| Civil engineering, masonry and formwork levelling | 1.0 mm/m | Masonry type / adjustable long type | ITC-600、ADL1.0-500 |
VI. Three common mistakes
Mistake 1: a longer body is more accurate.Length only determines how large an area one reading covers; sensitivity is set by the curvature of the bubble tube, and the two are unrelated. A 300 mm level in the 0.1 grade is far less accurate than a 150 mm one in the 0.02 grade. A long body is needed for large-span surfaces, not for high accuracy.
Mistake 2: cast iron is always worse than steel.FSK's bubble-tube levels use steel bases, which do wear better than traditional cast-iron products; but heavy precision flat / angular levels use painted cast iron (FC200), whose self-weight provides a seating stability that small steel levels cannot match. This is a difference in application, not in quality.
Mistake 3: overlooking the V groove and zero adjustment.Measuring cylindrical surfaces requires a V groove; and models with a zero-adjustment screw can be recalibrated in-house after the bubble tube drifts, which substantially lowers maintenance cost over time. Both features are standard on FSK precision flat / angular series, but may be absent on small and mini series — check the specification table before ordering.
VII. Flat or angular?
At the same sensitivity and accuracy class, FSK also offers two body styles, flat and angular:
- Precision flat level: the bottom face is the measuring surface, suited to flat plates, worktables and machine tool guideways. The full-flat base type (e.g. FLF3-200) achieves flatness within 0.003 mm and can serve as a reference.
- Precision angular level: V grooves on the bottom, top and left faces, with a flat right face, allowing measurement in both horizontal and vertical directions — suited to vertical spindles, columns and box-type workpieces.
A simple rule:Use a flat level for horizontal surfaces only; use an angular level when you also need vertical or cylindrical surfaces.
VIII. The short version
First fix the sensitivity grade (0.02 for machine tools / 0.05 for equipment / 0.5 and above for construction), then the accuracy class (JIS Class B or better if certification is required, standard grade for internal use), and finally choose flat or angular according to the shape of the surface and the nominal size according to the span. These three steps narrow FSK's 193 available levels down to 3–5 models.
If you are unsure which grade fits your conditions, send us the workpiece dimensions, accuracy requirement and whether a calibration certificate is needed, and we will recommend a model for your actual working conditions.