AMADA MM-123B Welding Monitor (Model MM-123B) is a AMADA Welding supplied by Guangzhou Yunke Electronics Co., Ltd. Welding monitor with an ISO 17657 toroidal coil and selectable RMS calculation for all measurement conditions.
Brand: AMADA | Category: AMADA Welding
Sales Inquiries: 15626018696 · 78403603@qq.com

| Model | MM-123B |
|---|---|
| Current Measurement Range | 0.100~2.000kA/1.00~20.00kA/10.0~200.0kA |
| Electrode Force Measurement Range | 0.30~6.00V/1.0~20.V |
| Weight | 1.9kg |
| External Dimensions W x D x H (mm) | 70*248*187 |
AMADA (Japan) MM-123B is a welding monitor that measures welding current, voltage, conduction time and displacement in real time and judges the results against upper and lower limits for weld quality control.
Higher measurement accuracy with an ISO 17657-compliant toroidal coil*; ISO 17657 RMS calculation under all measurement conditions; the conventional summed-average RMS calculation can also be selected.
Automotive parts, electrical components, motors, electronic components, semiconductors and ICs, batteries, medical devices and optical communications.
A typical configuration includes the welding power supply, welding transformer (AC type), welding head and monitor. Selection is based on the weld material, thickness and cycle time to determine current, pressurisation method and monitoring items.
Q: How do I determine the required welding power?
A: It is determined by the weld material, thickness and cycle time. The specification table for each model lists the maximum welding current or output power for an initial selection, which we then help confirm against your process.
Q: How do the power supply, welding head and monitor work together?
A: The power supply delivers the current waveform, the welding head applies pressure, and the monitor measures and judges the result; the three are selected together according to interface and range.
Q: Do you provide selection and after-sales support?
A: Guangzhou Yunke Electronics Co., Ltd. provides selection consulting, spare parts and after-sales support. Enquiries are welcome.
Q: What site conditions are required for installation?
A: Confirm the power supply capacity, air supply (for pneumatic press models), floor space and fume extraction/protection. Refer to the manual of the specific model for details.
All model codes, numbers and units are preserved verbatim from the original manufacturer datasheet. An English datasheet is available on request.
For a quotation, lead time or an optional calibration certificate, please contact our engineers.