DTT-2200NU Torque Testers (Model DTT-2200NU) is a Torque Testers supplied by Guangzhou Yunke Electronics Co., Ltd. DTT-2200NU Torque Testers — Torque Testers · Yunke Electronics. Request a quotation and datasheet.
Brand: See datasheet | Category: Torque Testers
Sales Inquiries: 15626018696 · 78403603@qq.com

| Model | DTT-2200NU |
|---|---|
| Maximum Torque | 2200 N·m |
| Measuring Range | 220~2200 N·m |
| Resolution | 1 N·m |
| Connection Head Dimensions | 1"( Control Method Hole) |
| Series | WIZTANK Number digits Torque Test Unit DTT-NU Series (Torque Sensor + Display Division Body Type) |
| Set | Torque Sensor ×1 + Display Controller ×1 + Connection Cable + AC / DC AC Adapter |
| Measuring Method | Torque Sensor Acquisition + Display Controller Number digits Display, can Correction Rotation / Rotation Dual toward Measurement |
| Accuracy (DTT-5NU and Upper) | ±0.5% or not Over Over ±3 Digits (CW / CCW) |
| Accuracy Range | Maximum Operation Value 20%~100%, and Digits ±1 not Meter |
| Operating Mode | No. a Peak (1st Peak) / Peak Hold (Peak Hold) / with (Track) three Type Mode Switching |
| Unit Switching | N · m, ft · lb, in · lb, kg · cm Type Unit can Free Switching |
| Warning Method | Buzzer + 6 LED Indication Lamp (1 + 5 ) Warning Value |
| Preset Functions | can Preset 10 groups Operating Value, a Key Switching |
| Data Storage | Peak Mode under Storable 250 groups Torque Value, supports Memory / / except / Output |
| Data output | supports USB Communication, Connection Electric can Data , Processing, Analysis, and Printing |
| Zero Digit Calibration | Open Unit Tool with Zero digits Automatic Calibration Functions |
| Power Saving Meter | can Preset Time Auto Power-off |
| Operating Temperature | -10℃~60℃ |
| Storage Temperature | -20℃~70℃ |
| Humidity | non-condensing can to 90% |
| Environment Test / Electromagnetic Compatible | via / via |
| Power Supply | AC / DC Rotation Replace Device (AC 100~240V Input) |
| Calibration Period | is Accuracy Accuracy, per years Calibration a times |
Some specification lines are quoted from the original manufacturer datasheet. Numbers, units and model codes are preserved verbatim; an English datasheet is available on request.
| Model | Max. Tack. N.m.m | Range of measurements N.m | Resolution | Console (English)! |
|---|---|---|---|---|
| DTT-05NU | 0.5 N·m | 0.100~0.500 N·m | 0.001 N·m | 1/4" |
| DTT-5NU | 5 N·m | 0.500~5.000 N·m | 0.001 N·m | 3/8" |
| DTT-50NU | 50 N·m | 5.00~50.00 N·m | 0.01 N·m | 3/8" |
| DTT-220NU | 220 N·m | 22.0~220.0 N·m | 0.1 N·m | 1/2" |
| DTT-550NU | 550 N·m | 55.0~550.0 N·m | 0.1 N·m | 3/4" |
| DTT-1000NU | 1000 N·m | 100~1000 N·m | 1 N·m | 1" |
| DTT-2200NU | 2200 N·m | 220~2200 N·m | 1 N·m | 1" |
Torque and production point inspections in the auto parts, electrical and electronics, hardware machinery, medical devices, aerospace and packaging; test subjects include preset / table / numerical open torque wrench, torque, electric start,_ Aerodynamic lifts, bottle caps and valves open to closed torque, stuns and so on. for routine count in the quality sector, and annual check and calibration in the measurement room for torque tools
Q: How to choose the two series DTT-NU and MTT-E? Q: What are the two series of MTT-E?
A: DTT-NU is of high accuracy, accuracy 0.5 per cent (minimal mass 0.7 per cent), sensors with monitor components, 6 with LED and bee-beeps, Validation and calibration of the torque tool for the metering room, quality department; MTT-E as a one-size economy, precision 1 per cent, mass overlay to 2000 N·m, suitable for rapid site inspection of the production line. The selection of DTT-NU is required for accuracy, and the selection of MTT-E for value for money and the torque cap is sought
Q: What about the DTT-NU slots?!
A: Select between the quantum 20% ~ 80% by the tox-squeaking tool: DTT-05NU (0.1 ~ 0.5 N·m)/ DTT-5NUScreech Stick Stick DTT-5NU Stick :Voice Z Z ; of the United Nations; of the United Nations; of the United Nations; of the United Nations; of the United Nations; of the United Nations; of the United Nations; General assembly and stringing tool DTT-50NU; medium-high torque DTT-220NU/ DTT-550NU; heavy load and large hardware DTT-1000NU/ DTT-2200NU. X-X-X-X-X-X-. X-X-X-X-X-X-X-X-X-X-X-X-X-X-X-X-X-X-X-X-X-X
Q: Why are sensors and monitors separated?
A: The fractional structure allows the sensor to be independently installed on a test table, clip or production line, and the display is placed in a position that is easy to observe, avoids readings of the inverse effects of measurements and facilitates the adaptation and upgrading of existing test stations
Q: Should annual calibration be required?
A: Officially recommend that the calibration be made annually to ensure accuracy is traceable; daily use of the advice is done on a shift basis and is reviewed in time after overload. helps to arrange the selection of calibration and supporting test tables, kits and kits. Reference: Yunke Electronics
All model codes, numbers and units are preserved verbatim from the original manufacturer datasheet. An English datasheet is available on request.
For a quotation, lead time or an optional calibration certificate, please contact our engineers.