Home › Products

Product Overview

Peacock 36B Precision Measuring Tools (Model 36B) is a Precision Measuring Tools supplied by Guangzhou Yunke Electronics Co., Ltd. Peacock 36B Precision Measuring Tools — Precision Measuring Tools · Yunke Electronics. Request a quotation and datasheet.

Brand: Peacock | Category: Precision Measuring Tools

Sales Inquiries: 15626018696 · 78403603@qq.com

Peacock 36B Precision Measuring Tools

Technical Specifications

Model36B
BrandPEACOCK JapanPeacock( Type OZAKI MFG.CO.,LTD.)
SeriesPEACOCK Type
Product TypeMechanical Dial Indicators(Standard Pointer Type)
Graduation0.01 mm
Measuring Range3 mm
Scale Reading±0 -25- 50
Indication Error MPE (1 / 10 Rotation)8 µm
Indication Error MPE (1 / 2 Rotation)11 µm
Indication Error MPE (1 Rotation)12 µm
Indication Error MPE (Full Range)16 µm
Hysteresis Error (Hysteresis)4 µm
Repeatability3 µm
Measuring Force1.4 N or less
Official Featuresstandard Contact Point (X-107); Back cover with lug (Rotatable lug 90°); Dial Diameter Ø40.8 mm
Applicable StandardJIS B 7503: 2017(Japan Standard Indicator)
Official Dimensions (Dimensions, Mm)A 46.2 mm, B 30.5 mm, C 12.9 mm, D 40.8 mm, E 12.5 mm, F 19 mm, G 4 mm, H 5.1 mm, I 37 mm, J 8.0 mm(Dimension code per official drawing)
OriginJapan( OZAKI MFG.CO.,LTD.)

Some specification lines are quoted from the original manufacturer datasheet. Numbers, units and model codes are preserved verbatim; an English datasheet is available on request.

Product Description

PEACOCK PEACOCKMini-indicators (0.001 / 0.005 / 0.01 mm)which corresponds to JIS B 7503: 2017. The airframe is compact and the table diameter is small, especially suitable for measurements on a test object or in a narrow space36BSpecifications: PEACOCK JIS B 7503 X-107 0.01 mm 3 mm 8 µm 16 µm 4 µm 3 µm 1.4 N 40.8 mm 1 10 90 2017 MPE OZAKI MFG CO LTD. Please contact our engineers for the full technical wording.


Official size (dimenions, unit ~, bit code corresponds to official size)

Location code_Other Organiser_Other OrganiserABCDEFGHIJ
Dimensions (mm)_em_em46.230.512.940.812.51945.1378.0

PEACOCK mini-specific comparison (official HPs extract, 6 models)A-ZX

ModelGraduationMeasuring rangeIndicator error 1/10 transferSplitIndicator error full processHysteresisRepeatabilityForce Measurement
5S0.001 mm1 mm5 µm10 µm4 µm2 µm1.5 N
470.01 mm4 mm8 µm18 µm4 µm3 µm1.4 N
47F0.01 mm4 mm8 µm18 µm4 µm3 µm1.4 N
57S0.01 mm5 mm8 µm18 µm4 µm3 µm1.4 N
36A0.005 mm3 mm6 µm12 µm3.5 µm3 µm1.4 N
36B0.01 mm3 mm8 µm16 µm4 µm3 µm1.4 N

The above table is an extract of the official specifications of all the 6 models of the PEACOCK minitypes, which are quoted directly from the official table of the HPs, The lateral comparison is facilitated by the selection of the selected type: the default area is determined by the range of measurements and the fractional values, and the indicator error slot meets the accuracy of the position, and the specific model is determined by the hierarchies of the back cover, oil resistance, low-calculation, lifting poles, etc

III. Key Product Advantages

IV. Industries and Typical Applications

V. FAQ

Q: Is 36B a percentage table or a thousand scale? What are the fractions and the range of measurements?
A: Officially marked fraction value 0.01 mm, range (Raay) 3 mm, which is known as percentage table according to national custom. The fraction value is the amount of the small cells on the table. The range of measurements is an effective process for the poles, which cannot be mixed: the fractions determine which readings can be fined and the range of measurements determines how far and how far the differentials can be measured

Q: Why is the "indicator error MPE" in the argument table in four?
A: Officially given 1/10 rotation, 1/2 rotation,. 1 transfer to full range maximum permissible error in four: this model is 8 µm/ 11 µm/ 12 µm/ 16 µm. The more the loops are turned, The greater the accumulated error, the maximum value for the full step. When you actually use it, it is more meaningful to refer to the error in the trans-routing of 1/10 if you do only a small trip. QuestSSSSSSS

Q: What about the back cover form (with ear cover / flat cover)?
A: The two measures are identical, with only the different way of installing the back cover. The back of the ear is fitted with an ear that can be directly stuck on the staircase or the tester; the back of the flat is a flat surface suitable for the frame trap or for the dedicated positioning plate. This model is: eardeep. The clips are selected in the form of a clamp, and the new pairs confirm the support interface

Q: What's the measure? Do the software pieces press on deformation?
A: Officially marked measures 1.4 N below. When you are concerned about the pressure transformation, you should select the official low-calculation type (subfixed to E, initial pressure 0.4 N) when you are looking at film, sheet, plastic, rubber or a very delicate component

Q: Can you use it in workshops with cutting fluids and dust? Q
A: The official description frame reverses are sealed by the O-ring and the back by fillings, which are used for waterproofing the dust structure in the general workshop environment. It is recommended that the official oil-resistant type (suffix SWA/SWF) be selected. Note that the structure is not capable of soaking or high-pressure flushing and that the connection and back caps are removed with reduced protection

Q: Can the head and the holster be changed? How are the accessories matched?!?
A: Yes. The official labels the head of the model (e.g., the header of the label (X-107); the back of the ear (the earrings can rotate 90°); the diameter of the table 40.8 mm) Standards of the model in the parameterZX) of the standard The header is reusable and can be replaced with a sphere, plane, needle, etc., by the shape of the work; the drum is of different diameters by type (commonly 6.35 mm, ZQ4, 10 mm)., magnetic tabs, 8 mm, 10 mm.Stands, magnetic tabs, etc.s, Stands First-class accessories Guangzhou Yunke Electronics can be combined and the order type is sufficient

Q: What support can Guangzhou Yunke Electronics provide?
A: The full series of percentage tables for PEACOCK PEACOCK, the selection of the 1,000 scale, the support set with magnetic tablets, the first-class vulnerability measures and daily usage and maintenance advice are available and invited for quotations

All model codes, numbers and units are preserved verbatim from the original manufacturer datasheet. An English datasheet is available on request.

For a quotation, lead time or an optional calibration certificate, please contact our engineers.

Related Products

Peacock LH-2 Precision Measuring Tools
Precision Measuring Tools

Peacock LH-2 Precision Measuring Tools

LH-2
└ Peacock (Japan)
Peacock LB-14 Precision Measuring Tools
Precision Measuring Tools

Peacock LB-14 Precision Measuring Tools

LB-14
└ Peacock (Japan)
Peacock LB-9 Precision Measuring Tools
Precision Measuring Tools

Peacock LB-9 Precision Measuring Tools

LB-9
└ Peacock (Japan)
Peacock LB-8 Precision Measuring Tools
Precision Measuring Tools

Peacock LB-8 Precision Measuring Tools

LB-8
└ Peacock (Japan)
Peacock LB-7V Precision Measuring Tools
Precision Measuring Tools

Peacock LB-7V Precision Measuring Tools

LB-7V
└ Peacock (Japan)
Peacock LB-7S Precision Measuring Tools
Precision Measuring Tools

Peacock LB-7S Precision Measuring Tools

LB-7S
└ Peacock (Japan)