FLUKE 115C (Model 115C) is a FLUKE supplied by Guangzhou Yunke Electronics Co., Ltd. FLUKE 115C — FLUKE · Yunke Electronics. Request a quotation and datasheet.
Brand: FLUKE | Category: FLUKE
Sales Inquiries: 15626018696 · 78403603@qq.com

| Maximum Voltage between Any Terminal and Ground | 600 V |
|---|---|
| Over Voltage Protection | 6 kV Peak, Compliant with IEC 61010-1 600 VCAT III, Pollution Degree 2 Gauge Setting |
| Display | Number digits: 6000 counts, per s more New 4 times |
| Specification | 33 Range, per s more New 32 Range |
| Operating Temperature | -10°C to + 50°C |
| Storage Temperature | -40°C to + 60°C |
| Battery Type | 9 V Alkaline Battery, NEDA 1604A / IEC 6LR61 |
| Battery Life | General Normal is 400 hours, No Backlight Lamp |
| DC Millivolt | Range / Resolution 600.0 mV / 0.1 mV |
| DC Millivolt Accuracy | ± ([% Reading] + [Counting Times]): 0.5% + 2 |
| DC Voltage | Range / Resolution 6.000 V / 0.001 V / 60.00 V / 0.01 V / 600.0 V / 0.1 V |
| DC Voltage Accuracy | ± ([% Reading] + [Counting Times]): 0.5% + 2 |
| AC Voltage (Millivolt)¹ True RMS | Range / Resolution 600.0 mV / 0.1 mV |
| AC Voltage (Millivolt)¹ True RMS Accuracy | 1.0% + 3(DC, 45 Hz to 500 Hz) / 2.0% + 3(500 Hz to 1 kHz) |
| AC Voltage ¹ True RMS | Range / Resolution 6.000 V / 0.001 V / 60.00 V / 0.01 V / 600.0 V / 0.1 V |
| AC Voltage ¹ True RMS Accuracy | 1.0% + 3(DC, 45 Hz to 500 Hz) / 2.0% + 3(500 Hz to 1 kHz) |
| Specification | Range / Resolution 600 Ω / 1 Ω |
| Accuracy | Buzzer Open when 250 Ω; Detection to / 500 μs or more Length Time Open Circuit or Circuit. |
| Ohm | Range / Resolution 600.0 Ω / 0.1 Ω / 6.000 kΩ / 0.001 kΩ / 60.00 kΩ / 0.01 kΩ / 600.0 kΩ / 0.1 kΩ / 6.000 MΩ / 0.001 MΩ |
| Ohm Accuracy | 0.9% + 1 |
| Ohm Range / Resolution | 40.00 MΩ / 0.01 MΩ |
| Ohm Accuracy | 5% + 2 |
| Diode Test | Range / Resolution 2.00 V / 0.001 V |
| Diode Test Accuracy | 0.9% + 2 |
| Capacitance | Range / Resolution 1000 nF / 1 nF / 10.00 μF / 0.01 μF / 100.0 μF / 0.1 μF / 9999 μF / 1 μF / 100 μF to 1000 μF |
| Capacitance Accuracy | 1.9% + 2 |
| Capacitance Range / Resolution | > 1000 μF |
| Capacitance Accuracy | 5% + 20% |
| Lo-Z Capacitance | Range 1 nF to 500 μF |
| Lo-Z Capacitance Accuracy | 10% + 2 µδΠΝ |
| AC Current (Ampere) True RMS / (45 Hz to 500Hz) | Range / Resolution 6.000 A / 0.001 A / 10.00 A / 0.01 A |
| AC Current (Ampere) True RMS / (45 Hz to 500Hz) Accuracy | 1.5% + 3 / 20 A Overload most Length up to 30 s |
| DC Ampere | Range / Resolution 6.000 A / 0.001 A / 10.00 A / 0.01 A |
| DC Ampere Accuracy | 1.0% + 3 / 20 A Overload most Length up to 30 s |
| Hz(Voltage or Current Input)² | Range / Resolution 99.99 Hz / 0.01 Hz / 999.9 Hz / 0.01 Hz / 9.999 kHz / 0.001 kHz / 50.00 kHz / 0.01 kHz |
| Hz(Voltage or Current Input)² Accuracy | 0.1% + 2 |
| Dimensions | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) |
| Weight | 550 g |
| Warranty Period | 3 years |
Some specification lines are quoted from the original manufacturer datasheet. Numbers, units and model codes are preserved verbatim; an English datasheet is available on request.
Designed for electrical technicians and manufactured by Fluke. Fluke 115C is a compact and effective value instrument for field maintenance technicians. There are also Fluke 114 electrical scales, which are used to measure the use of electricity and electronics.Stamps for electrical and electronic testing.Stands for electrical and electronic testing.Stands for electrical and electronic testing.s for electrical and electronic testing.ssSt Fluke 116C HVAC with temperature and microassay function is useful for all electricians with non-contact voltage measurement functions Fluke 117C Useable for all electrical utility with non-contact voltage QQQQQ Q Table
Electrical parameters such as voltage, currents, resistance are used as the basic tools for electrical installation, equipment repair and discharge; the selection is primarily concerned with the validity of the values, CAT security level, accuracy and bandwidth
Q: What can FLUKE Fluke 115C digital master table do?
A: FLUKE Fluke 115C digital table is a digital table product for FLUKE Fluke. he main functions listed officially include white LED backlighting, which can be read effectively even in weaker places; electrical resistance and continuity; minimum/ max/ mean measurement function, which records signal fluctuations. If the type is selected according to working conditions, the measurement object and process requirements may be provided and confirmed with cloud assistance
Q: What are the key technical indicators for 115C?
A: This page is based on official information and contains a total of 40 items covering technical specifications/precision specifications/mechanical and general specifications. For more detailed accuracy and environmental conditions, please refer to the official manual, which is not open on the page..St.St.St.St.s.St.St.St.sSt.St.Sp.Sp
Q: How can the selection and the cargo date be confirmed?!
A: Guangzhou Yunke Electronics Co., Ltd. supplies a full range of FLUKE Fluke products, which can provide selective advice, technical information and post-sale support. Please provide a specific model, quantity and usage profile, which will be confirmed with the assistance of staff
Q: What is the FLUKE Fluke 115C digital master table? What are the scenarios?
A: This product is a digitally-owned table (FLUKE Fluke/ Digitally-based table). It is used for measuring electrical parameters such as voltage, currents, resistance and is a basic tool for electrical installation, equipment repair and discharge; The selection is primarily concerned with valid values, CAT security level, accuracy and bandwidth
Q: How can technical support be obtained after purchase?!
A: Products with official instructions and quality assurance services; Guangzhou Yunke Electronics Co., Ltd. provides pre-sale selection and post-sale coordination services, which can be submitted through site contact, supported by staff assistance to connect to the original plant
All model codes, numbers and units are preserved verbatim from the original manufacturer datasheet. An English datasheet is available on request.
For a quotation, lead time or an optional calibration certificate, please contact our engineers.