Home › Products

Product Overview

FLUKE 1503 (Model 1503) is a FLUKE supplied by Guangzhou Yunke Electronics Co., Ltd. FLUKE 1503 — FLUKE · Yunke Electronics. Request a quotation and datasheet.

Brand: FLUKE | Category: FLUKE

Sales Inquiries: 15626018696 · 78403603@qq.com

Technical Specifications

AccuracyRange 600.0 V
Resolution0.1 V
50 Hz to 400 Hz ± (Reading% + Digits)±(2% + 3)
Input3 MΩ(Nominal), < 100 pF
Total Minus Rate (1 kΩ Not Balance)DC when > 60 dB, 50 or 60 Hz
Overload Protection600 V rms or DC
Range / Resolution20.00 Ω 0.01 Ω
200.0 Ω0.1 Ω
2000 Ω1.0 Ω
20.00 kΩ0.01 kΩ
Accuracy±(1.5% + 3)
Overload Protection2 V rms or DC
Test Voltage> 4.0 V, < 8 V
Current> 200.0 mA
Measuring Value Range0.01 MΩ to 2000 MΩ
Test Voltage500 V、1000 V
Test Voltage Accuracy+ 20%,- 0%
Current1 mA(Nominal)
Automatic DischargingDischarging Time < 0.5 s, C = 1 µF or more
with Electric Electric Indicatorat Test Front, such as Terminal Voltage > 30 V, Control Test
Maximum Capacitance Loadat 1 µF or less Load can Operation
Output VoltageDisplay Range Resolution Test Current Precision Standard degrees / ±(% Reading + most Low Effective Digits Quantity)
500 V (0% to + 20%)0.1 to 20.0 MΩ 0.01 MΩ 1 mA @ / 500 kΩ ± (2.0% + 5)
500 V (0% to + 20%) 20.0 to 200.0 MΩ0.1 MΩ
500 V (0% to + 20%) 200 to 500 MΩ1 MΩ
1000 V (0% to + 20%)0.1 to 200.0 MΩ 0.1 MΩ 1 mA @ / 1 MΩ ± (2.0% + 5)
1000 V (0% to + 20%) 200 to 2000 MΩ1 MΩ
Plus to Terminal Maximum Voltage:600 V AC rms or DC
Storage Temperature-40°C to 60°C(-40°F to 140°F)
Operating Temperature-20°C to 55°C(-4°F to 131°F)
Temperature CoefficientTemperature 28°C(82°F) when, 0.05 x(Specified Accuracy) / °C
VibrationSupplied, 2 g, 5-500 Hz, MIL-PRF-28800F 2 Class Instrument
Specificationper IEC 61010-1 No. 2 Version Gauge Setting, 1 m (1 m Test, six Surface, Place Plate)
EMC Compatibilityat a pcs 3 V / M RF Magnetic internal, Accuracy = Specified Accuracy (EN 61326-1:1997)
SafetyCompliant with ANSI / ISA 82.02.01 (61010-1) 2004, CAN / CSA-C22.2 NO. 61010-1-04, and IEC / EN 61010-1 No. 2 Version, IV Class Measurement 600 V (CAT IV)
CertificationCSA per Standard CSA / CAN C22.2 No. 61010.1-04; TUV per Standard IEC / EN 61010-1 No. 2 Version
Batterycells AA Battery (NEDA 15A or IEC LR6)
Battery LifeInsulation Test Application: Chamber Temperature Conditions under, New Alkaline Battery can For Instrument Gauge to 1000 times Insulation Test. Standard Yes at will 1000 V via 1 MΩ Resistance under Measure , Operating Period is 5 seconds Open, 25 seconds .
Resistance Measuring:Chamber Temperature Conditions under, New Alkaline Battery can For Instrument Gauge to 2500 times Grounding Connection Insulation Measurement. Standard Yes at 1 Ω Resistance under Measure , Operating Period is 5 seconds Open, 25 seconds .
Dimensions (Height X Width X Length)5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
Weight550 g (1.2 lb)
IP IP RatingIP40
AltitudeOperating Altitude 2000 m CAT IV 600 V, 3000 m CAT III 600 V
Operation (Storage)12000 m
Over Quantity Capability110% Range
Internal incl. AccessoriesTL224 Test Test Lead, TP74 Test Probe, Clamp Zero pcs No. is 1958654() and 1958646(), sets and Range Probe

Some specification lines are quoted from the original manufacturer datasheet. Numbers, units and model codes are preserved verbatim; an English datasheet is available on request.

Product Description

Product Overview

Fluke 1503 insulation test system is very elaborate, robust and very easy to operate. As many different tests of voltage are accepted, they become numerous repairs, The ideal tools for debugging and preventive maintenance settings, which are also equipped with other components such as remote probes, make the testing process very fast and save costs. A demonstration of the routine operation of the insulation resistor Handheld bridges (electricity/composive/resistance tester) FlukeAMB. Reference: LCR55A

Key Advantages

  1. Insulation test process: 0.1 M to 2000 MScreen ScreenScreak Screllage of the

Category Description

Measurement of insulation resistance by applying a straight current voltage to be used in insulation assessment of electrical power, cable and distribution devices

Applied industry & test project

FAQ

Q: What can FLUKE Fluke 1503 insulation resistance tester do?

Specifications: Fluke FLUKE 1503 0.1 2000. Please contact our engineers for the full technical wording.

Q: What are the key technical indicators for 1503?

A: The list of parameters for this page has been compiled by official information and contains a total of 51 items covering communication/direct current voltage measurement/train connection resistance measurement/insulation specifications/common technical indicators. For more detailed accuracy and environmental conditions, please refer to the official manual and this page is not open article by article.!

Q: How can the selection and the cargo date be confirmed?!

A: Guangzhou Yunke Electronics Co., Ltd. supplies a full range of FLUKE Fluke products, which can provide selective advice, technical information and post-sale support. Please provide a specific model, quantity and usage profile, which will be confirmed with the assistance of staff

Q: What is the type of FLUKE Fluke 1503 insulation resistance test? What are the scenarios?

A: This product is an insulation resistor test (FLUKE Fluke/ insulation resister test). The insulation resistance is measured by applying a straight current voltage to be used in the insulation state assessment of electrical power, cable and distribution devices

Q: How can technical support be obtained after purchase?!

A: Products with official instructions and quality assurance services; Guangzhou Yunke Electronics Co., Ltd. provides pre-sale selection and post-sale coordination services, which can be submitted through site contact, supported by staff assistance to connect to the original plant

All model codes, numbers and units are preserved verbatim from the original manufacturer datasheet. An English datasheet is available on request.

For a quotation, lead time or an optional calibration certificate, please contact our engineers.

Related Products

FLUKE FLK-EV KIT
FLUKE

FLUKE FLK-EV KIT

FLK-EV KIT
└ Insulation Resistance Testers
FLUKE 1577
FLUKE

FLUKE 1577

1577
└ Insulation Resistance Testers
FLUKE 1555 10 kV
FLUKE

FLUKE 1555 10 kV

1555 10 kV
└ Insulation Resistance Testers
FLUKE 1550C FC Kit
FLUKE

FLUKE 1550C FC Kit

1550C FC Kit
└ Insulation Resistance Testers
FLUKE 1550C
FLUKE

FLUKE 1550C

1550C
└ Insulation Resistance Testers
FLUKE 1508
FLUKE

FLUKE 1508

1508
└ Insulation Resistance Testers