Home › Products

Product Overview

SSD ZAPPⅡ-LS ESD Test Equipment (Model ZAPPⅡ-LS) is a ESD Test Equipment supplied by Guangzhou Yunke Electronics Co., Ltd. SSD ZAPPⅡ-LS ESD Test Equipment — ESD Test Equipment · Yunke Electronics. Request a quotation and datasheet.

Brand: SSD | Category: ESD Test Equipment

Sales Inquiries: 15626018696 · 78403603@qq.com

SSD ZAPPⅡ-LS ESD Test Equipment

Technical Specifications

ModelZAPPⅡ-LS
Input Power SupplyDC24 V±10%
Capacity2.4VA
Output VoltageAC Approx. 2000 V
Discharging MethodHeight AC Electric Discharging Type
Balance±5V or less (Distance 50mm, Output )
Alarm Output (ALARM)NPN Light Electric Electric Device Output, Maximum Current 100mA, plus Voltage 30V DC or less
Check Output (C.C)NPN Light Electric Electric Device Output, Maximum Current 100mA, plus Voltage 30V DC or less
Discharging Input (HV-OFF)Discharging : and 0V Circuit; Discharging Allowable: Open Circuit ( Voltage 0.5V or less)
Origin Quantity0.03ppm or less ( Air Flow Quantity 10ℓ / min(ANR), Output Port 300mm)
Working FluidNet Air
Operating Pressure Range0.005~0.2MPa
Operating Air Flow QuantityMaximum 50ℓ / min(ANR)
Operating EnvironmentRange Temperature: 10~40 ℃ Range Humidity: ~65% or less but not Condensation
Body DimensionsΦ16×100.5mm Control Part 86.5L×18W×50H (excluding Part)
Body WeightApprox. 145g (3 points groups, Cable 1m when)
MaterialControl Part: ABS, not Steel
ProductControl Part, Electric Extreme Part, Connection Wire (1m), Input Power Cable

Some specification lines are quoted from the original manufacturer datasheet. Numbers, units and model codes are preserved verbatim; an English datasheet is available on request.

Product Description

(a) A HF de-electrication device (nozzle type) under the SSD Sicily flag. It is a HF de-electrication device PIEZONIZER. It is in the form of a nozzle type (cable internal air tube). HF de-electrication device (nozzle type) HF SD (SHISHIDO Eurositic, LTD.) was founded in the year 1938 as a Japanese manufacturer of specialized electrostatic countermeasures, At the core of the original HDC-AC high frequency ionizing technology, the product covers the entire range of deelectrication, dust removal, electrostatic measurements and anti-statistical appliances

Structure and working principles:!PIEZONIZER series, using voltage transformers, will press DC24V into high frequency voltage, create high frequency dizziness at the discharge needles, generate ions, and release ions from the nozzle/gun by compressed air, Efficient electricity removal in small volumes; directly internal to the equipment when the high voltage is miniaturized

Product characteristics

• Applied sceneSemiconductor electronics, liquid crystal panels, assembly processes, base plate fittings, testing processes, printing and coating processes, packaging and bundles, resin formation, film, glass, mirrors, dust, non-species, vibration conveyors, proximity,. (c) The production and testing process for static-sensitive manufacturing and testing, such as in provincial spaces

Main specificationsType: ZaPPII-LS; input power: DC24 V10 per cent; capacity: 2.4 VA; output voltage: AC about 2000 V; XC:Stamp:Stamp:Stamp:Stamp:Stamp:Stamp:Stamp:Stamp:Stamp:Stamp:Stamp:Stand (a) Discharge mode: HF AC electrodischarge; ion balance: 5V (distance from 50mm, default from plant); Warning output (ALARM): NPN photorelay output, maximum current 100mA, pressurized 30V DC below; Clean-check output (C.C.): NPN photorelay output, maximum current 100mA, applying voltage 30V DC. Full parameters are shown in the following specification table

Use and select tipsThe small-calibre nozzle is suitable for loading small spaces or for de-electrifying local points; the gun is suitable for hand-held handling.Air is used in a clean dry air and is used in the range of pressure that is recommended in the instruction.?Appointment

Maintenance and maintenance: clean up with specialized cleaning tools when discharge needles accumulate; keep gas clean and air well in the range of specifications; shut down the gas and power sources before long-term decommissioning.: to the end of the use of the power supply

Guangzhou Yunke Electronics Co., Ltd. provides selective advice, technical information and post-sale support for SSD products such as product catalogues, drawing data (DXF) or technology PDF, which is welcomed by call

Q: Is this a Japanese original?

A: Yes. This is the original Japanese product SHISHIDO EurosatIC (SSD West Sitty), with Guangzhou Yunke Electronics Co., Ltd. for marketing and technical support

Q: How can price and cargo dates be obtained without price?!

A: The price is not displayed on this page. the price and the date of the goods are requested to contact Guangzhou Yunke Electronics Co., Ltd., and we will respond to the model and quantity as soon as possible

Q: What are the requirements for ion generator gas?

A: Please use clean dry air (excluding moisture and oil) and provide air in the pressure range indicated in the official specification table; air pipes use clean pipe with specified outer diameter

Q: Can selective advice and technical information be provided?

A: Yes. We can provide selection advice based on your use environment (distance, wind speed, temperature, blast protection requirements, etc.) and official product catalogues, drawings (DXF) and technical information (PDF)

Q: What parameters are the main parameters for the selection of electrical decomposition devices?

A: General emphasis is given to identifying: the distance and speed requirements, the need for extra gas connections, the size and beat of the electrically removed, the use of the environment (temperature/cleanness/explosiveness) and the specifications of the supporting power source or control. We welcome, when not certain, the fact that we are on the ground and that we are the ones who are the ones who are the ones to help us. —

Q: How do you deal with quality assurance and after sale?!?

A: This item is accompanied by an official instructions of use. The quality of non-anthropogenic damage is dealt with in the factory terms, depending on the order confirmation; the consumables (discharge needles, filters, etc.) are normal wear and tear, and can be ordered for replacement.? — A: This item is attached to the official instructions of use.. Quality of non-anthropogenic damage is addressed by the manufacturer, depending on the order

All model codes, numbers and units are preserved verbatim from the original manufacturer datasheet. An English datasheet is available on request.

For a quotation, lead time or an optional calibration certificate, please contact our engineers.

Related Products

SSD IRYSYS ESD Test Equipment
ESD Test Equipment

SSD IRYSYS ESD Test Equipment

IRYSYS
└ SSD
SSD EXPLOSION-PROOF ESD Test Equipment
ESD Test Equipment

SSD EXPLOSION-PROOF ESD Test Equipment

EXPLOSION-PROOF
└ SSD
SSD S-250 ESD Test Equipment
ESD Test Equipment

SSD S-250 ESD Test Equipment

S-250
└ SSD
SSD 35S/20S ESD Test Equipment
ESD Test Equipment

SSD 35S/20S ESD Test Equipment

35S/20S
└ SSD
FeaturedSSD DP ESD Test Equipment
ESD Test Equipment

SSD DP ESD Test Equipment

DP
└ SSD
SSD H0110-S4B ESD Test Equipment
ESD Test Equipment

SSD H0110-S4B ESD Test Equipment

H0110-S4B
└ SSD