I. Internal or external measurement first
The KROEPLIN (Kroeplin GmbH, Germany) caliper gauge line looks like a large model range, but the first level of classification is very simple —check whether the anvils go inside a bore or clamp around the outside of the workpiece. The 126 KROEPLIN caliper gauges currently listed on our site split neatly into three groups on this basis:
- Internal measurement (66 models): 25 internal caliper gauges, 20 blind-bore caliper gauges, 16 three-point internal caliper gauges, 5 internal comparators
- External measurement (54 models): 18 external caliper gauges, 18 pipe-wall caliper gauges, 18 thickness caliper gauges
- Special-purpose measurement (6 models): bottle-neck caliper gauges (for aerosol can necks)
Settling this first level immediately cuts the choice by more than half. Each category is explained below.
II. Comparison table of the eight categories
| Category | What it measures | Measuring range span | Contact point type | Available |
|---|---|---|---|---|
| Internal caliper gauge | Through bores, stepped bore diameters | 2.5~150 mm | Ball tip Φ2 | 25 models |
| Blind-bore caliper gauge | Blind bores, diameters near the bore bottom | 20~100 mm | Conical SR0.2 | 20 models |
| Three-point internal caliper gauge | Self-centring bore diameter, roundness | 7~105 mm | Ball tip Φ1 | 16 models |
| Internal comparator | Large bore diameters by comparison method | 50~430 mm | Ball tip Φ2 | 5 models |
| External caliper gauge | Shaft diameter, thickness, width | 0~100 mm | Ball tip Φ1.5 | 18 models |
| Pipe-wall caliper gauge | Wall thickness of round pipes and vessels | 0~100 mm | — | 18 models |
| Thickness caliper gauge | Thickness of film, foam and soft materials | 0~100 mm | Flat Φ50 | 18 models |
| Bottle-neck caliper gauge | Aerosol cans, bottle-neck diameters | 3.5~29 mm | — | 6 models |
III. The four internal types: blind bores are the easiest to get wrong
Of the four internal series, internal caliper gauges and blind-bore caliper gauges are the most often confused, but they cannot replace each other.
Blind bores require the blind-bore type.A standard internal caliper gauge has its two contacts at the tip of the jaw; reaching near the bottom of a bore requires sufficient overhang. Blind-bore gauges use conical SR0.2 contacts positioned closer to the tip, so they can reach the bottom of a blind bore. Using a standard internal gauge on a blind bore makes the jaw bottom out first and the reading is completely wrong.
| Series | Applicable bore type | Measuring depth L Max | Representative models |
|---|---|---|---|
| Internal caliper gauge | Through bores, deep cavities | 85~395 mm | L350、L250、H850 |
| Blind-bore caliper gauge | Blind bores | 85 mm | G2G80、G2G70、G2G60 |
| Three-point internal caliper gauge | Bores requiring self-centring | 84 mm | G285P3、G270P3 |
| Internal comparator | Bores above 50 mm | 85~170 mm | H4M300、H2M130 |
What are three-point gauges for?A standard internal caliper gauge makes a two-point measurement, so the operator has to find the maximum diameter position manually and human influence is significant. A three-point internal caliper gauge self-centres with three contacts: insert it and the reading is the true bore diameter, with good repeatability — well suited to fast 100% inspection on a production line. The trade-off is a narrow range (each instrument covers only a 20 mm band, e.g. G285P3 covers 85–105 mm), so one instrument handles only one size band.
Large bores use a comparator.Beyond 300 mm, standard internal caliper gauges no longer reach; an internal comparator is used — a comparison method where you zero against a setting ring or gauge block first, then measure the workpiece, which is why it is dial-indicating (H4M300 covers 300–430 mm with 0.05 mm indication accuracy).
IV. The three external types: pipe wall and thickness are not the same
This is the pair most often confused among external gauges.Pipe-wall gauges measure the wall thickness of rigid round tubes, while thickness gauges measure the thickness of soft materials such as film and foam, and the distinguishing feature is the contact point:
- Pipe-wall caliper gauge (K series with R): e.g. K8R100(0~100mm)、K4R50S (0–50 mm), with a maximum measuring depth of 382 mm, allowing wall thickness to be measured deep inside a tube.
- Thickness caliper gauge (C series with T): uses flat Φ50 contacts, whose large contact area will not sink into film, foam or rubber. Measuring soft materials with ball contacts deforms the material under the measuring force and gives a reading that is too low — the large flat Φ50 contact is designed precisely for this.
- External caliper gauge (K series): ball Φ1.5 contacts for external dimensions of rigid workpieces such as shaft diameters, thicknesses and widths, e.g. K450(0~50mm)、K330S(0~30mm)。
A rule of thumb:If the workpiece can be deformed by measuring force (film, foam, soft rubber), choose a thickness gauge; for rigid tubes, choose a pipe-wall gauge; for external dimensions of solid rigid parts, choose an external gauge.
V. One special-purpose type: bottle-neck caliper gauges
Aerosol cans and spray bottles have dedicated standards for neck diameter, and the contacts of a general-purpose gauge do not match the shape. KROEPLIN's bottle-neck series concentrates on the 3.5–29 mm range, for example AE2105 covers 4.50–5.60 mm (digital) and A2100 covers 25–29 mm (dial). These are industry-specific instruments; confirm the applicable bottle-neck standard number before ordering.
VI. Digital or dial?
Of the 126 caliper gauges available, 79 are digital and 47 are dial, roughly a 60/40 split. The choice is driven not by accuracy but by how the instrument is used:
- Choose digital: when data must be recorded, when connecting to SPC, when the operator needs an unambiguous direct reading, and for high-frequency measurement on production lines.
- Choose dial: for simple on-site comparison, when "in tolerance or not" is enough, in harsh environments (oil, moisture) where electronics are a concern, and when budget is tight. Dial models of the same specification are usually cheaper than digital ones.
One notable pattern: the larger the series, the more it leans towards dial. The internal comparator series is entirely dial (comparison measurement is more intuitive on a dial for reading deviation), while three-point and blind-bore types, which need absolute readings, are entirely digital.
VII. A five-question selection method
Answer these five questions in order and you can narrow 126 models down immediately:
- Internal or external measurement? → determines the first level (66 internal / 54 external / 6 special-purpose)
- Is it a blind bore? → within internal measurement, rule out or lock in the blind-bore series
- What is the actual workpiece size? → caliper gauges have stepped ranges; each instrument covers only a 20–50 mm band, so you must choose the one covering your workpiece. For a 60 mm bore, select the 50–70 mm L250 rather than the 0–50 mm model.
- How deep must the jaw reach? → check "Measuring depth L Max"; choose the L series for deep cavities (up to 395 mm), the G series is sufficient for shallow bores
- Reading type? → digital / dial, based on the criteria in the previous section
VIII. A note on accuracy specifications
One point should be stated plainly: among the 126 KROEPLIN caliper gauges on this site, the internal, external, pipe-wall and internal comparator series have stated indication accuracy in their specification tables (commonly 0.01 mm / 0.05 mm / 0.1 mm, relaxed as the range increases); however, for the 39 models in the blind-bore (20), three-point (8), bottle-neck (6) and thickness (5) series, the factory specification sheets give no uniform nominal value. This is because accuracy in these categories depends strongly on the specific conditions (material hardness, contact wear, zero-setting method); the calibration report supplied with the instrument is authoritative.
If your selection has a hard accuracy requirement, request the actual calibration report for that model when ordering and we will help confirm it with the manufacturer.
IX. The short version
Internal or external → blind bore or not → which range band the workpiece falls in → how deep → digital or dial. These five steps reduce KROEPLIN's 126 caliper gauges to 1–2 models. Send us the workpiece size, bore type (through / blind) and measuring depth and we will match you to a specific model.