Home › Products

Product Overview

SHIMPO DTMX-20C Tension Meters (Model DTMX-20C) is a Tension Meters supplied by Guangzhou Yunke Electronics Co., Ltd. SHIMPO DTMX-20C Tension Meters — Tension Meters · Yunke Electronics. Request a quotation and datasheet.

Brand: SHIMPO | Category: Tension Meters

Sales Inquiries: 15626018696 · 78403603@qq.com

SHIMPO DTMX-20C Tension Meters

Technical Specifications

ModelDTMX-20C
Range2.00~20.00daN(Rated 19.61daN(20.00kgf))
Accuracy±1.5% R.C.(Meter Measure Wire when)
Display4 digits LCD , digits Height 11.5mm
Response Time0.5s / 1s / 2s / 4s levels Adjustable
Measuring Wire Upper Limit1000 m / min, can at Wire Detection, No requires Unit
Reading MemoryThis unit 100 groups Measurement Data + Maximum / Minimum / Peak / Average / Standard Deviation Statistics
Data output✅ Analog 0~1VDC + RS-232C/Mitutoyo Digital Output (DTMB No Output)
Body MaterialPressure Aluminium Housing, Electric,
Dimensions76(W) × 48(D) × 257(L) mm
Total WeightApprox. 700g
Power Supply4 cells AA Alkaline Battery (Approx. 20 hours); can with AC AC Adapter
Operating Environment0~45℃, Relative Humidity ≤90%, non-condensing
Standard AccessoriesMain unit, Guide toward groups, AA Alkaline Battery, Portable Instrument Case, Manual

Some specification lines are quoted from the original manufacturer datasheet. Numbers, units and model codes are preserved verbatim; an English datasheet is available on request.

Product Description


ModelRated capacityEffective measurement of rangeAccuracySuggested line diameter%
DTMX-0.2C196.1cN(200.0gf)0.0~200.0cN±1% R.C.Cylinder wires 0.08mm below; copper wire 0.15mm below; fibre-optic 1000D below
DTMX-0.5C490.3cN(500.0gf)4.0~500.0cN±1% R.C.Cylinder 0.01; copper wire 0.05 0.25mm 0.25mm. Reference: 0.15mm
DTMX-1C981cN(1000gf)100~1000cN±1.5% R.C.Cylinder 0.05; copper wire 0.1 0.4mm 0.4mm. Reference: 0.25mm
DTMX-2C1961cN(2000gf)200~2000cN±1.5% R.C.Cylinder 0.15; copper wire 0.3 0.6mm 0.6mm. Reference: 0.4mm
DTMX-2.5C2452cN(2500gf)250~2500cN±1.5% R.C.Cylinder 0.15; copper wire 0.3 0.6mm 0.6mm. Reference: 0.4mm
DTMX-5C4903cN(5000gf)500~5000cN±1.5% R.C.Cylinder 0.3; copper wire 0.4 1.0mm 1.0mm. Reference: 0.7mm
DTMX-10C9.81daN(10.00kgf)1.00~10.00daN±1.5% R.C.Cylinder 0.4; copper wire 0.7 1.2mm 1.2mm. Reference: 0.8mm
DTMX-20C19.61daN(20.00kgf)2.00~20.00daN±1.5% R.C.Crude wire; special calibration of customer sample lines

III. Core strengths

  1. Simulates output with RS-232C/ numerical output with 0 ~ 1V, where the tension value can enter PLC in real time, recorder or top machine, for closed ring control and curve archiving
  2. The unit stores and automatically counts the 100 data sets (max/minimum/peak/average/standard deviation) without hand-copying
  3. The thickness compensation automatic calibration + field 1.5% step-by-step fine-tuning, no re-routing, one covering various processes
  4. 5 type of wire preset (bar, wire, copper line + 2 group custom sample line), switch one key
  5. The highest level of support is provided for the online measurement of the 1000 m/min, which is a direct reading during the silk walk without the suspension of the sampling
  6. Aluminium alloy casings, resistant to shock and static power, suitable for dual-use workshops and laboratories
  7. Handheld or fixed online dual-use, with the selection of AC adapters for long-term online monitoring..Spunners

IV. Applicable industries

Online tension detection and data tracking of running line items such as fibre-optic cables, paint-packed copper wires, textile fibres, carbon fibres, molten silk, metal wires, film/ tape curling, chords, batteries and polar wires are traced. —

V. OPTIONAL . Reference: FAQ

Q: What about the DTMX-20C and DTMB?
A: The measure is the same as accuracy. DTMB has no output, only local readings, low prices; DTMX with RS-232C/ numerical output and simulation output, memory 100 group data, Computer/PLC or DTMX must be selected when data are to be traced.Spun:Spun.St

Q: Can a DTMX simulation output directly enter PLC?Spwx1
A: It is possible to export 0 — 1 VDC , with load resistance 2k more than once, with direct access to PLC analogue Input or Chart Recorder

Q: How thick are the lines?
A: The standard applicable line material for DTMX-20C is the rough wire; the customer sample line is specially calibrated. The line is too rough-chamber and easy to skim and beyond the range it is recommended to choose a dedicated wheel component or to re-select a larger slot

Q: Can you measure the film, the flatband? Q: Can
A: No, this series can only measure the diameter of the radial material.??

Q: How long can the battery last?!?
A: Section 4 AA Alkaline Battery has been used continuously for approximately 20 hours; long-term online use of the recommended AC adapter. X Qu XX

All model codes, numbers and units are preserved verbatim from the original manufacturer datasheet. An English datasheet is available on request.

For a quotation, lead time or an optional calibration certificate, please contact our engineers.

Related Products

SHIMPO DTMX-10C Tension Meters
Tension Meters

SHIMPO DTMX-10C Tension Meters

DTMX-10C
└ SHIMPO
SHIMPO DTMX-5C Tension Meters
Tension Meters

SHIMPO DTMX-5C Tension Meters

DTMX-5C
└ SHIMPO
SHIMPO DTMX-2.5C Tension Meters
Tension Meters

SHIMPO DTMX-2.5C Tension Meters

DTMX-2.5C
└ SHIMPO
SHIMPO DTMX-2C Tension Meters
Tension Meters

SHIMPO DTMX-2C Tension Meters

DTMX-2C
└ SHIMPO
SHIMPO DTMX-1C Tension Meters
Tension Meters

SHIMPO DTMX-1C Tension Meters

DTMX-1C
└ SHIMPO
SHIMPO DTMX-0.5C Tension Meters
Tension Meters

SHIMPO DTMX-0.5C Tension Meters

DTMX-0.5C
└ SHIMPO