MOTIVE MTM-20N Force Gauges (Model MTM-20N) is a Force Gauges supplied by Guangzhou Yunke Electronics Co., Ltd. MOTIVE MTM-20N Force Gauges — Force Gauges · Yunke Electronics. Request a quotation and datasheet.
Brand: MOTIVE | Category: Force Gauges
Sales Inquiries: 15626018696 · 78403603@qq.com

| Model | MTM-20N |
|---|---|
| Series | MTM |
| Sensor Type | built-in Sensor a Body Type |
| Range | 20N(Approx. 2.04 kgf) |
| Displayed Value | 20.00N (2.000 kgf) |
| Resolution | 0.01N (0.001 kgf) |
| Accuracy | Official Product page not Single Accuracy; Same Hardness pcs Flat units MT Series Official Nominal ±0.5%, Part Division Catalogue ±1% F.S, Actual by Supplied Check is Standard. |
| Main Unit Dimensions | Length 176 × Width 74 × Height 29 mm |
| Sampling Rate | 1000 times / s (MTM / MTA / MTF is 2 kHz) |
| Overload Capacity | 200% Full Range |
| Memory Functions | 1000 pcs Data Quantity Value |
| Data output | RS232C / USB / Analog -2~+2V / Comparison Signal |
Some specification lines are quoted from the original manufacturer datasheet. Numbers, units and model codes are preserved verbatim; an English datasheet is available on request.
MOTIVE Taiwan MOTIVE QMTM-20NA digital thruster of the internal sensors belonging to the MTM series with a range 20N, with a displayed value 20.00N (2.000 kgf). Resolution 0.01N (0.001 kgf). MTM is a OLED screenshotr platform for MOTIVE: the high OLED screen can be read clearly and sampled at a frequency of 2 kHz, Three digital interfaces with USB/RS-232/RS-485 MODBUS support the G-8 language menu and can also extend the sensor into a mechanical test platform. The airframe, which is 176 x 74 x 29 mm, is one of the most lightly designed types in the same range and is suitable for full-scale, space-limited production line inspection
| Model | Range | Displayed Value | Resolution | Equivalent kgf | Equivalent British_Equal British |
|---|---|---|---|---|---|
| MTM-2N | 2N | 2.000N (200.0 gf) | 0.001N (0.1 gf) | 203.9 gf | 7.19 ozf |
| MTM-5N | 5N | 5.000N (500.0 gf) | 0.001N (0.1 gf) | 509.9 gf | 1.124 lbf |
| MTM-10N | 10N | 10.00N (1.000 kgf) | 0.01N (0.001 kgf) | 1.02 kgf | 2.248 lbf |
| MTM-20N | 20N | 20.00N (2.000 kgf) | 0.01N (0.001 kgf) | 2.04 kgf | 4.496 lbf |
| MTM-50N | 50N | 50.00N (5.000 kgf) | 0.01N (0.001 kgf) | 5.1 kgf | 11.24 lbf |
| MTM-100N | 100N | 100.0N (10.00 kgf) | 0.1N (0.01 kgf) | 10.2 kgf | 22.48 lbf |
| MTM-200N | 200N | 200.0N (20.00 kgf) | 0.1N (0.01 kgf) | 20.4 kgf | 44.96 lbf |
| MTM-500N | 500N | 500.0N (50.00 kgf) | 0.1N (0.01 kgf) | 51 kgf | 112.4 lbf |
| MTM-1000N | 1000N | 1000.0N (100.0 kgf) | 1N (0.1 kgf) | 102 kgf | 224.8 lbf |
Q: How do you choose the measure?
A: The nearest range is selected by the measured value of 1.5 ~ 2. This model size 20N (approximately 2.04 kgf) Resolution 0.01N (0.001 kgf), which recommends that the test force normally fall to the full mass of the 20% ~ 100%; If the measured force value is only below 10 per cent of the full range for a long time, it is recommended that a smaller level be changed to obtain a better and effective resolution
Q: What are the relationships between the three series of MTM, MTA, MT? Q: What are the relationships between the three series of MTM, MTA, MT, Z
A: Three persons share the same official list (officially marked MTM (MTA)-xN) with the same size as 176 x 74 x 29 mm, which is the same size as the other two, and the same size as the other two. The files are 2N ~ 1000N in 9. The difference is in functional positioningMTMis a standard type of built-in sensor, with three digital interfaces of 2 kHz sampled with USB/ RS-232/ RS-485 MODBUS; ; XV XV XV Q ; X XVMTAThis is the basis for moving output with the power - the position shift curve - in conjunction with the platformMTThe order is high-end, with real-time clocks, progress bars and kiki (customs) data uploaded. the order. the order. the suffix..Scortage
Q: What use is RS-485 MODBUS?
A: The instrument can be placed directly on the industrial site's RS-485 bus, using standard MODBUS protocol reading force values and determinations, without the need for USB to be attached to each set, Fits for multiple-worker centralized collection lines
Q: Can you get the sensors?
A: Yes. MTM supports the outer sensor, which can be selected for combination of outer sensors for the equivalent process when it needs to be reached into a clip, platform or narrow working slot
Q: Can you use the automation?Assem
A: Yes. Except for the RS232C/ USB digital interface, Also available -2 ~ +2 V Simulation of voltage output and +NG / OK / -NG open arctic comparison signal (MAX Z) XXC 10 mA) The automatic up and downs and the eligibility determination can be made directly from PLC, which is accompanied by the electrodynamic power station. Reference: 30 V
Q: How does precision be called? Can it be traced?!!?
A: The official product pages are not singled out for accuracy; with the hardware platform's MT series of official designations 0.5%, some distributors'directory 1%F.S,SS-S-S-S-S-S-S-S-S-S-S-S-S-S-S-S-S-S-S-S-S-S-S-S-S-S-S- The random inspection of the accomplishment book is used as the basis for the inspection process, which is carried out in accordance with the relevant protocols such as JJG, which requires third party measurements; and the daily verification of the site is conducted using standard instrumentation or calibrated code matching
Q: What should be the watchful side of daily usage?!?
A: 1 The force shall be directed at the sensor axis to avoid side-direction and bending; 2 Do not remain for long beyond 110 per cent and be discharged in time after warning; 3 Battery low voltage instructions appear and charged in a timely manner. Long-term absences should also be repeated at intervals;4 the environment is generally 0 ~ +40 °C, 20 ~ 80 % RH, avoiding condensation, Corrosionable gases and strong vibration environments;5 Regularly used standard gauges or coded verifications to maintain traceability.5
All model codes, numbers and units are preserved verbatim from the original manufacturer datasheet. An English datasheet is available on request.
For a quotation, lead time or an optional calibration certificate, please contact our engineers.