MOTIVE Z2S-LC-20N Force Gauges (Model Z2S-LC-20N) is a Force Gauges supplied by Guangzhou Yunke Electronics Co., Ltd. MOTIVE Z2S-LC-20N Force Gauges — Force Gauges · Yunke Electronics. Request a quotation and datasheet.
Brand: MOTIVE | Category: Force Gauges
Sales Inquiries: 15626018696 · 78403603@qq.com

| Model | Z2S-LC-20N |
|---|---|
| Series | Z2S-LC |
| Sensor Type | external Sensor (Single toward Pressure Dedicated) |
| Range | 20N(Approx. 2.04 kgf) |
| Displayed Value | 20.00N (2.000 kgf) |
| Resolution | 0.01N (0.001 kgf) |
| Accuracy | ±0.2%(MOTIVE Official to Z2S Series Nominal Accuracy). |
| Main Unit Dimensions | Length 220.5 × Width 78 × Height 32.3 mm |
| Sampling Rate | 1000 times / s (MTM / MTA / MTF is 2 kHz) |
| Overload Capacity | 200% Full Range |
| Memory Functions | 1000 pcs Data Quantity Value |
| Data output | RS232C / USB / Analog -2~+2V / Comparison Signal |
Some specification lines are quoted from the original manufacturer datasheet. Numbers, units and model codes are preserved verbatim; an English datasheet is available on request.
MOTIVE Taiwan MOTIVE QZ2S-LC-20NSpecifications: Z2S-LC 20N 20.00N 2.000 kgf 0.01N 0.001 kgf. Please contact our engineers for the full technical wording. Reference values: 2.Specialized in compression teststhe sensor is marked in the direction of pressure only and thus a better compressed measurement performance than the general two-way machine is obtained at the same volume, suitable for key pressure, bullet compression, packaging resistance, Material pressure and pressure are in place to determine such a pressure-only event. Hosts use 0.2% accuracy, 1000 times/ seconds for the full output._. Reference: Z2
| Model | Range | Displayed Value | Resolution | Equivalent kgf | Equivalent British_Equal British |
|---|---|---|---|---|---|
| Z2S-LC-2N | 2N | 2.000N (200.0 gf) | 0.001N (0.1 gf) | 203.9 gf | 7.19 ozf |
| Z2S-LC-5N | 5N | 5.000N (500.0 gf) | 0.001N (0.1 gf) | 509.9 gf | 1.124 lbf |
| Z2S-LC-10N | 10N | 10.00N (1.000 kgf) | 0.01N (0.001 kgf) | 1.02 kgf | 2.248 lbf |
| Z2S-LC-20N | 20N | 20.00N (2.000 kgf) | 0.01N (0.001 kgf) | 2.04 kgf | 4.496 lbf |
| Z2S-LC-50N | 50N | 50.00N (5.000 kgf) | 0.01N (0.001 kgf) | 5.1 kgf | 11.24 lbf |
| Z2S-LC-100N | 100N | 100.0N (10.00 kgf) | 0.1N (0.01 kgf) | 10.2 kgf | 22.48 lbf |
| Z2S-LC-200N | 200N | 200.0N (20.00 kgf) | 0.1N (0.01 kgf) | 20.4 kgf | 44.96 lbf |
| Z2S-LC-500N | 500N | 500.0N (50.00 kgf) | 0.1N (0.01 kgf) | 51 kgf | 112.4 lbf |
Q: How do you choose the measure?
A: The nearest range is selected by the measured value of 1.5 ~ 2. This model size 20N (approximately 2.04 kgf) Resolution 0.01N (0.001 kgf), which recommends that the test force normally fall to the full mass of the 20% ~ 100%; If the measured force value is only below 10 per cent of the full range for a long time, it is recommended that a smaller level be changed to obtain a better and effective resolution
Q: Can you measure the stretching force?
A:No, I can'tMOTIVE officially specifies that Z2S-LC is a one-way compression special type, which only measures the pressure direction. If you need to measure both pressure and pull, you can also use the pressure to control the pressure. Please select Z2 (inner two-way) or Z2S-DPU (outside two-way)
Q: Can you use the automation?Assem
A: Yes. The official MOTIVE reply is that "it can be connected to the automation equipment through PLC" and that the electrical voltage machine can be used to auto-pressure, and the decision and data records are in place
Q: What is the accuracy of the test? Q
A: The official designation of Z2S series as. Reference: MOTIVE±0.2%For precision measurements, check the results randomly or the third-party calibration results
Q: Z2S-LC and Z2S-DPU
A: Both series are outer sensors. Only the compressor, which is expected to perform the best in the compressed period, is selected for Z2S-LC; the sensor is required to pull both directions or to carry a metal shield (DPU) to withstand field collisions._ Choose Z2S-DPU.!
Q: Can you use the automation?Assem
A: Yes. Except for the RS232C/ USB digital interface, Also available -2 ~ +2 V Simulation of voltage output and +NG / OK / -NG open arctic comparison signal (MAX Z) XXC 10 mA) The automatic up and downs and the eligibility determination can be made directly from PLC, which is accompanied by the electrodynamic power station. Reference: 30 V
Q: How does precision be called? Can it be traced?!!?
A: 0.2 per cent (officially known accuracy of the Z2S series). Randomly accompanied by a check of accomplishment book, which can be sent in accordance with the relevant protocols such as JJG if it is required to be measured by a third party;;Systems of the Z2S series;Systems of the Systems of the Systranges; Daily verification in the field can be conducted using standard gauges or calibrated calibrated code matching. Reference: MOTIVE
Q: What should be the watchful side of daily usage?!?
A: 1 The force shall be directed at the sensor axis to avoid side-direction and bending; 2 Do not remain for long beyond 110 per cent and be discharged in time after warning; 3 Battery low voltage instructions appear and charged in a timely manner. Long-term absences should also be repeated at intervals;4 the environment is generally 0 ~ +40 °C, 20 ~ 80 % RH, avoiding condensation, Corrosionable gases and strong vibration environments;5 Regularly used standard gauges or coded verifications to maintain traceability.5
All model codes, numbers and units are preserved verbatim from the original manufacturer datasheet. An English datasheet is available on request.
For a quotation, lead time or an optional calibration certificate, please contact our engineers.