FISCHER DUALSCOPE H FMP150 Coating Thickness Gauge (Model DUALSCOPE H FMP150) is a Thickness Gauges supplied by Guangzhou Yunke Electronics Co., Ltd. FISCHER DUALSCOPE H FMP150 three-principle gauge, touchscreen and Windows CE, thick conductive coatings and nickel layers, inspection plans.
Brand: See datasheet | Category: Thickness Gauges
Sales Inquiries: 15626018696 · 78403603@qq.com

| Model | DUALSCOPE H FMP150 |
|---|---|
| Measuring Method | Magnetic (DIN EN ISO 2178)+ Magnetic (DIN EN ISO 2178)+ Flow (DIN EN ISO 2360)—— three Type Management at a |
| Applicable Substrates | Steel / Ferrous (Fe) and Non-ferrous metals (NF: Aluminium, Copper, Brass etc.) |
| with Measuring Capability | can at Steel / Ferrous above Measurement Thickness and Guide Electric Non- Magnetic Property Coating, also can Measurement with above Layer; to etc. , Layer and Copper Layer can at a times Measurement in Same when Measure and Division Display |
| Series | FISCHER DUALSCOPE FMP100 / H FMP150 Series ( Type, can Replace Probe) |
| Brand / Origin | Germany Helmut Fischer GmbH(Fischer, Germany pcs) |
| Measuring Range | Depends on Coating / Substrate Combination and Use Probe (This unit excluding Probe, requires per Measurement task optional) |
| Probe | Replaceable, with FISCHER Manufacturer High-precision probes (incl. FD10 etc. Dual Probe and each Class Dedicated Probe); Automatic probe recognition |
| Substrate Recognition | Automatic |
| Display | Height Resolution Display, with Keypad, Available or Indicator Operation |
| Operation Welding Systems | Windows CE(Diagram User Interface) |
| Interface Management Management | Text pcs / Text pcs Clamp Structure can by User Customisable, Interface can pcs Property Setting |
| Measured Value Memory | Large Capacity Memory Device, can Capacity Number pcs Measurement Application and Number pcs Reading |
| Communication Interface | USB, with Printing Unit Interface |
| Limit Value Monitoring | Over Output Limit Value when Sound Indication |
| Calibration | Operation Guide Type Calibration, Flow Range |
| Measuring Acquisition | Single times Measurement, Mean Memory, Surface Region Continuous Measurement ( Probe Rear Output Mean), Display, Normal Value Automatic except, Measurement |
| Statistics and Evaluation | Data and most Statistics, Direct Method Diagram, Area Frequency, FDD Diagram, Evaluation |
| Inspection Plan (Optional) | Fischer DataCenter IP Inspection Plan Software (This Series Dedicated, requires ), can at PC above Inspection Plan and Installed to Instrument, Guide Operation Measurement |
| Interface Language | supports Multi Type and Language |
| Applicable Standard | DIN EN ISO 2178(Magnetic , Magnetic ), DIN EN ISO 2360( Flow ) |
| Warranty | Subject to terms of sale |
Some specification lines are quoted from the original manufacturer datasheet. Numbers, units and model codes are preserved verbatim; an English datasheet is available on request.
The DUALSCOPE H FMP150 is the three-principle handheld gauge in the FISCHER DUALSCOPE FMP100 / H FMP150 series. It combines a high-resolution touchscreen with Windows CE and uses magnetic induction, the magnetic method and the eddy current method with automatic substrate recognition. Automatic probe recognition and interchangeable original FISCHER probes let one instrument be configured for different coating / substrate combinations.
Beyond magnetic induction and eddy current, it adds the magnetic method, making it the most capable model in the series. In addition to non-magnetic coatings and platings on steel and insulating coatings on non-ferrous metals, it measures thick, conductive non-magnetic coatings on steel / iron and nickel layers on non-ferrous metals. On printing rollers, chromium and copper layers can be read together in one measurement and displayed separately.
The DUALSCOPE® FMP100 and DUALSCOPE® H FMP150 are Helmut Fischer's high-precision handheld gauges for the most demanding quality-assurance work. Both use a high-resolution touchscreen (stylus or finger, with a virtual keyboard) and Windows CE, organising measuring applications through graphical menus and a user-defined file / folder structure. Automatic probe recognition and automatic substrate recognition, together with Fischer's wide range of original high-precision probes (including FD10 dual probes and special-purpose types), cover everything from the thinnest plating to thick coatings.
Measurement is based on magnetic induction (DIN EN ISO 2178) for non-magnetic coatings on steel / iron and the eddy current method (DIN EN ISO 2360) for insulating coatings on non-ferrous metals. DUALSCOPE® instruments integrate both principles and switch between steel and non-ferrous metals without changing instrument; on duplex coatings on steel (paint / hot-dip zinc) both layer thicknesses can be read in one measurement and shown separately.
Quality control, series production, incoming inspection and laboratory measurement, for sampling as well as full inspection; the statistical functions also support process monitoring. Typical applications include vehicle body paint and KTL coatings, electroplating and anodised layers, heavy-duty corrosion protection (paint / zinc duplex systems), anodic films on aluminium extrusions, and printing rollers where several layer thicknesses must be read in one measurement and displayed separately.
Guangzhou Yunke Electronic Co., Ltd. supplies FISCHER coating thickness gauges with selection advice, quotations, demonstrations and after-sales support, and can provide original probes, calibration standards, measuring stands and software on request. The instrument is supplied without a probe, so please ask our engineers to confirm the right probe and coating / substrate combination before ordering.
The specification table above is transcribed from Helmut Fischer GmbH official product documentation; no values have been converted or rewritten. Where the manufacturer does not publish dimensions, weight or ingress-protection ratings, those fields are left blank. This is a quotation-only catalogue and no prices are listed.
For a quotation, lead time, a demonstration, the DataCenter IP software or help choosing a probe, please contact our engineers.