PHYNIX Surfix Pro X Coating Thickness Gauge (Model SurfixProX) is a Thickness Gauges supplied by Guangzhou Yunke Electronics Co., Ltd. PHYNIX Surfix Pro X flagship probe gauge, colour graphic display, 100,000 readings, USB 2.0 and Bluetooth 4.0, SSPC PA2 / 90-10 statistics, probes up to 30 mm.
Brand: See datasheet | Category: Thickness Gauges
Sales Inquiries: 15626018696 · 78403603@qq.com

| Model | Surfix Pro X |
|---|---|
| Series | PHYNIX Surfix Pro X Series ( Division Body Type) |
| Category | Type Division Body Coating Thickness Gauges(external Replaceable Probe) |
| Brand / Origin | Germany PHYNIX(PHYNIX Sensortechnik GmbH, Germany Control ) |
| Measuring Principle | Probe and Setting: F Probe Magnetic (DIN EN ISO 2178); N Probe Current (DIN EN ISO 2360); FN Combination Probe Automatic Switching |
| Probe Type | external Replaceable Probe, compatible PHYNIX Full Series Probe (Standard Probe, Direct Angle Probe, Probe) |
| Measuring Range | Depends on Probe, Maximum can up to 30 mm |
| Accuracy | Depends on Probe, Maximum can up to ±(0.7μm + of reading 1%) |
| Resolution | 0.1μm or < of reading 0.2% |
| Probe Measure | Hardness () |
| Calibration Method | Calibration, Zero Calibration, Single Calibration, Dual Calibration, CTC Calibration |
| Statistical Functions | Single Value / Value Statistics: n, Average, Standard Deviation, Minimum, Maximum, Kvar, cp, cpk, SSPC PA2, 90 / 10 Gauge then |
| Division | Diagram (Chart), Direct Method Diagram (Histogram) |
| Data Storage | up to 100,000 pcs Measured values (Direct Memory + Data Storage), Text pcs can Customisable |
| Calibration Memory | up to 1,000 groups Standalone Calibration |
| Data Transfer | USB 2.0 / Bluetooth 4.0 |
| Continuous Measuring | per s 3 pcs Reading ( Mode) |
| Display | Height Resolution Diagram Display (with Backlight) |
| Operating Temperature | 0 ℃ ~ +60 ℃ |
| Surface Temperature | -15 ℃ ~ +60 ℃(standard); with Height Temperature Measurement can up to +150 ℃ or +300 ℃ |
| Dimensions | 137 × 66 × 23 mm |
| Weight | 223 g(incl. FN 1.5 Probe and Battery); Single Unit 148 g |
| Power Supply | 2 cells AA Battery / 2 cells AA NiMH Rechargeable Battery (supports USB ) / USB Power Supply |
| IP Rating | IP 52(Dustproof, Protection Water) |
| Applicable Standard | DIN、ISO、ASTM、BS |
| Single Language | Multi Language Single (, , , in Text etc.) |
| Supplied Accessories | Main unit (incl. Probe), Rubber Protection sets, 2 Plate Calibration , Zero Standard Foil (Steel / Aluminium), USB Wire, 2 cells AA Battery, PHYNIX.connect Transfer Software, Operating Manual, Manufacturer Certificate, Instrument Case |
| Warranty | 2 years |
Some specification lines are quoted from the original manufacturer datasheet. Numbers, units and model codes are preserved verbatim; an English datasheet is available on request.
The Surfix Pro X is PHYNIX's flagship instrument, and its defining feature is a high-resolution colour graphic display. The high-contrast, high-brightness screen stays readable from a distance or in darkness, and lets the operator analyse data graphically on site through trend charts and histograms. A multilingual graphical menu makes the instrument intuitive enough to use without consulting the manual.
To meet the "Industry 4.0" requirement that measuring instruments connect to production control systems, the Surfix Pro X provides both USB 2.0 and Bluetooth 4.0 interfaces for straightforward integration into fully networked production environments. Memory holds up to 100,000 measured values with user-defined file names for archiving, and up to 1,000 independent calibrations can be stored. Combined with the interchangeable PHYNIX probes, this delivers the highest accuracy and convenient handling in almost any application.
PHYNIX is the coating thickness gauge brand of PHYNIX Sensortechnik GmbH, based in Neuss, Germany (Siemensstr. 14, D-41469 Neuss). Instruments are developed and built in Germany under a DIN EN ISO 9001 certified quality management system. Across the range the probe tips are made of tungsten carbide for extremely high wear resistance and long service life, and the probe foot carries a V-groove that seats squarely on flat, cylindrical and curved surfaces.
Two measuring principles are used: magnetic induction (DIN EN ISO 2178) for non-magnetic coatings on ferromagnetic substrates (Fe: steel, iron), and the eddy current method (DIN EN ISO 2360) for insulating coatings on non-ferrous metals (NFe: aluminium, zinc, copper, brass). FN combination probes identify the substrate and switch principle automatically without operator intervention.
PHYNIX gauges measure non-destructively and are used in electroplating, paint and powder coating, automotive manufacture and appraisal, chemical processing, aerospace, shipbuilding, and quality control of steel structures and heavy-duty corrosion-protection coatings. Switch on and measure — the instruments suit incoming inspection, in-process sampling, final inspection and laboratory work.
Guangzhou Yunke Electronic Co., Ltd. supplies the full PHYNIX range with selection advice, quotations, demonstrations and after-sales support, and can provide factory calibration certificates and accessories (probes, reference plates, calibration foils, high-temperature probe feet, carrying cases) on request. Please ask our engineers to confirm the right probe range and substrate compatibility before ordering.
The specification table above is transcribed from PHYNIX Sensortechnik GmbH official datasheets and product pages; no values have been converted or rewritten. This is a quotation-only catalogue and no prices are listed.
For a quotation, lead time, a demonstration, an English datasheet or an optional factory calibration certificate, please contact our engineers.